This guide explains quick conversion between amps and milliamps for engineers and technicians worldwide reliably.
Includes formulas, tables, worked examples, unit definitions, and practical conversion calculator guidance for accuracy consistency.
Amps to milliamps and milliamps to amps conversion calculator (current magnitude)
Core concept: the ampere and the milliampere
The ampere (symbol A) is the SI base unit for electric current. The milliampere (symbol mA) is a derived unit equal to one thousandth of an ampere.
Conversion is linear and exact: 1 A = 1000 mA and 1 mA = 0.001 A. This provides direct arithmetic conversion suitable for automation and calculators.

Essential formulas for conversion
Amps to milliamps
Use the multiplication factor 1000.
- I_mA: current expressed in milliamps (mA).
- I_A: current expressed in amperes (A).
Typical values: small sensor currents often range 0.1 mA to 20 mA; typical DC power supplies for modules might deliver 0.01 A (10 mA) to 5 A.
Milliamps to amps
Use the division factor 1000.
- I_A: current in amperes (A).
- I_mA: current in milliamps (mA).
Typical values: instrumentation loops often use 4–20 mA (0.004–0.020 A); USB 2.0 ports provide up to 500 mA (0.5 A).
Variable definitions and typical measurement contexts
Precise understanding of variables and measurement contexts avoids unit errors in design or testing.
- Measured current (I): the instantaneous or DC current measured in the circuit.
- Rated current: the specified continuous current rating of a component or source.
- Sensing resolution: the minimum measurable increment; for a 12-bit ADC measuring 0–20 mA, resolution ≈ 20 mA/4095 ≈ 0.0049 mA.
Practical calculator rules and rounding guidance
When designing or documenting systems, choose rounding and significant figures consistent with measurement precision and safety margins.
- For instrument loop currents (e.g., 4–20 mA), display at least three significant figures (e.g., 12.345 mA) if ADC resolution supports it.
- For power supply ratings, round up to standard vendor values (e.g., 0.75 A requirement → specify 1 A or 800 mA supply).
- For reporting, use SI prefixes and avoid mixing units without explicit notation (e.g., write 0.005 A (5 mA)).
Extensive reference tables: common conversions (Amps to Milliamps)
| Amps (A) | Milliamps (mA) | Context / Typical device |
|---|---|---|
| 0.0001 A | 0.1 mA | High-sensitivity sensor leakage |
| 0.001 A | 1 mA | Small microcontroller standby |
| 0.005 A | 5 mA | Low-power indicator LED with resistor |
| 0.01 A | 10 mA | Some LED arrays, low-power modules |
| 0.02 A | 20 mA | Standard indicator LED typical forward current |
| 0.05 A | 50 mA | Small relay coil currents |
| 0.1 A | 100 mA | Bluetooth modules, small motors idle |
| 0.2 A | 200 mA | USB low-power devices in operation |
| 0.5 A | 500 mA | USB 2.0 maximum per port |
| 1 A | 1000 mA | Small DC motors, power rails |
| 2 A | 2000 mA | Phone rapid-charging circuits |
| 5 A | 5000 mA | High-current modules, motor drivers |
| 10 A | 10000 mA | Power distribution, industrial loads |
Extensive reference tables: common conversions (Milliamps to Amps)
| Milliamps (mA) | Amps (A) | Context / Typical device |
|---|---|---|
| 0.1 mA | 0.0001 A | Leakage current specifications |
| 1 mA | 0.001 A | Low-power sensor idle |
| 4 mA | 0.004 A | Minimum of industrial 4–20 mA loop |
| 20 mA | 0.02 A | Maximum of typical sensor/actuator loop |
| 50 mA | 0.05 A | Small relays, LEDs in series |
| 100 mA | 0.1 A | Portable device average draw |
| 500 mA | 0.5 A | USB 2.0 port capability |
| 1000 mA | 1 A | Power adapter output |
| 2000 mA | 2 A | Phone chargers and higher-power USB |
| 5000 mA | 5 A | Motor driver supply |
Accuracy considerations for measurement and conversion
When converting values programmatically or in documentation, consider the precision of the measuring instrument and the effect of rounding on downstream calculations such as power.
- Instrument accuracy: a 1% meter error for 20 mA corresponds to ±0.2 mA (±0.0002 A).
- ADC quantization: resolution depends on reference voltage and input scaling; ensure shunt resistor selection maps expected mA range into ADC input range with adequate margin.
- Temperature effects: shunt resistors drift with temperature coefficient (TC); a 100 ppm/°C shunt changes 0.01%/°C, which is relevant for precision mA-level measurements.
Formulas for related calculations (power, shunt resistor sizing)
Power from current and voltage
- P: power in watts (W).
- V: voltage across load in volts (V).
- I_A: current in amperes (A). If the current is provided in mA, convert: I_A = I_mA ÷ 1000.
Typical example values: 5 V supply and 100 mA draw → P = 5 × 0.1 = 0.5 W.
Shunt resistor to measure current with voltage-sensing ADC
- V_shunt: voltage across shunt resistor in volts (V).
- I_A: current in amperes (A).
- R_shunt: shunt resistance in ohms (Ω).
Choose R_shunt to produce safe measurable V_shunt within ADC input range while minimizing power loss: R_shunt = V_max_ADC ÷ I_max_A.
Worked example 1: Converting small-signal currents in a sensor chain
Problem statement: A sensor outputs 12.7 mA. Document the value in amperes for a power calculation and determine the power dissipated across a 10 Ω sense resistor.
Step-by-step solution
- Convert current to amperes using formula:
I_A = I_mA ÷ 1000
Substitute: I_A = 12.7 ÷ 1000 = 0.0127 A.
- Compute voltage across the sense resistor:
V_shunt = I_A × R_shunt
Substitute: V_shunt = 0.0127 × 10 = 0.127 V.
- Compute power dissipated in resistor:
P = V_shunt × I_A
Substitute: P = 0.127 × 0.0127 ≈ 0.0016129 W ≈ 1.613 mW.
- Interpretation: The 10 Ω resistor dissipates only 1.613 mW at 12.7 mA, so power rating of 0.125 W (1/8 W) is more than sufficient.
Notes: Maintain at least 2–3 significant figures consistent with measurement precision; here 12.7 mA implies three significant digits.
Worked example 2: Sizing a USB-powered device and documenting current
Problem statement: A handheld device measured average current draw 0.845 A under typical load. Convert to milliamps for user documentation and calculate required battery backup for 30 minutes operation at nominal 5 V.
Step-by-step solution
- Convert amperes to milliamps:
I_mA = I_A × 1000
Substitute: I_mA = 0.845 × 1000 = 845 mA.
- Compute energy consumption (watts) at 5 V:
P = V × I_A
P = 5 × 0.845 = 4.225 W.
- Compute required energy for 30 minutes (0.5 hours):
Energy = P × t
Energy = 4.225 W × 0.5 h = 2.1125 Wh.
- Convert Wh to mAh for a 5 V battery specification:
Battery_capacity_mAh = (Energy_Wh ÷ Voltage_V) × 1000
Battery_capacity_mAh = (2.1125 ÷ 5) × 1000 = 422.5 mAh.
- Apply design margin: choose at least 20% margin → required ≈ 507 mAh; select a standard 600 mAh battery for reliability.
Documentation: State device draw as 845 mA (0.845 A) and recommend minimum battery capacity 600 mAh to achieve ~30 minutes operation with margin.
Implementation tips for an efficient conversion calculator
Design considerations for calculators used in manuals, software, or embedded systems:
- Input validation: accept numeric values with optional SI suffix (e.g., "5 A", "500 mA") and parse correctly.
- Unit normalization: convert parsed input to base units (A) internally, perform arithmetic, then render user-selected units.
- Precision controls: allow user to select rounding (significant digits or decimal places) and present both units for clarity.
- Edge cases: handle extremely small or large values using scientific notation and consider overflow/underflow in embedded environments.
Automation examples and pseudo-algorithm
Simple algorithm steps for an API or embedded function to convert between A and mA:
- Parse input value and unit token.
- If unit token is "mA", compute I_A = value ÷ 1000; else if "A", compute I_mA = value × 1000.
- Apply rounding as requested and return both numeric results with explicit units.
Implementation note: Use 64-bit floating point for general-purpose calculators; for embedded microcontrollers with tight resources, use fixed-point arithmetic with scaling factor 1000 to avoid floating-point overhead.
Safety and compliance note for current handling
When specifying conversions for system design, consider electrical safety standards and component ratings. Continuous currents must not exceed cable, trace, connector, or fuse ratings.
- Follow local and international electrical safety codes for conductor sizing and overcurrent protection.
- Account for inrush currents: some devices draw transient peak currents well above steady-state values (e.g., motors, capacitive charging circuits).
- For instrumentation loops, adhere to explosion-proof or intrinsic-safety requirements if operating in hazardous environments.
Standards, normative references, and authoritative resources
Refer to primary standards and guidance documents for unit definitions, measurement, and documentation best practices:
- International Bureau of Weights and Measures (BIPM) — SI Brochure (official definitions of SI units): https://www.bipm.org/en/publications/si-brochure
- National Institute of Standards and Technology (NIST) — Guide for the Use of the International System of Units (Special Publication 811): https://www.nist.gov/pml/special-publication-811
- IEEE Standards Association — for electrical engineering practice and measurement standards: https://standards.ieee.org
- IEC (International Electrotechnical Commission) documentation for electrical component ratings and marking conventions: https://www.iec.ch
These sources provide authoritative definitions and guidance for unit usage, notation, and measurement traceability in engineering documentation.
Common pitfalls and troubleshooting checklist
A checklist prevents common errors when converting and documenting currents in technical systems:
- Verify unit labels on measured data — ambiguous labels like "mA" vs "A" cause costly mistakes.
- Check instrument calibration and measurement uncertainty before publishing converted values.
- Confirm whether reported currents are RMS, peak, or DC; conversions between units are identical but subsequent power calculations depend on waveform type.
- For multi-channel systems, ensure aggregate currents do not exceed supply or trace capacity.
SEO and documentation best practices for conversion content
To optimize for search and usability, structure documentation around user intents and common queries:
- Include keyword variations: "amps to milliamps", "mA to A converter", "convert A to mA", and "current unit conversion calculator".
- Provide immediate answers near the top of pages: show concise formulas and a compact conversion table for quick reference.
- Offer worked examples and downloadable tables to support engineers and technicians with reproducible calculations.
- Use canonical external references (BIPM, NIST, IEC) to improve trust signals for search engines and technical readers.
Advanced considerations for signal conditioning and measurement chains
When measuring mA-level currents precisely, the conversion between mA and A is trivial, but measurement chain design is critical.
- Shunt selection trade-offs: larger R_shunt increases voltage and improves ADC resolution but increases power loss and thermal drift.
- Instrumentation amplifiers: use low-offset, low-drift amplifiers for differential measurement across small shunts.
- Isolation: for high-side or grounded measurement, consider isolated amplifiers or Hall-effect sensors to avoid common-mode and safety risks.
- Filtering: implement appropriate low-pass filtering to reduce noise when converting instantaneous measurements to average mA or A values; ensure filtering does not obscure transient faults.
Appendix: quick conversion cheat sheet
| Common notation | Conversion formula | Quick example |
|---|---|---|
| mA → A | I_A = I_mA ÷ 1000 | 20 mA → 0.020 A |
| A → mA | I_mA = I_A × 1000 | 0.5 A → 500 mA |
| Power (W) | P = V × I_A | 12 V × 0.5 A = 6 W |
| Shunt voltage | V_shunt = I_A × R_shunt | 0.05 A × 1 Ω = 0.05 V |
Further reading and tools
Useful online and reference tools for engineers performing conversions and related calculations:
- BIPM SI Brochure — exact definitions of ampere and prefixes: https://www.bipm.org/en/publications/si-brochure
- NIST Special Publication 811 — authoritative SI usage guide: https://www.nist.gov/pml/special-publication-811
- IEEE Standards portal — for applied electrical measurement standards and best practices: https://standards.ieee.org
- Manufacturer datasheets — for shunt resistors, ADCs, and amplifier selection consult vendor technical documentation for precise TC and tolerance values.
Final operational checklist for documentation and calculators
- Display both units when possible (e.g., "0.845 A (845 mA)").
- State assumed precision and measurement uncertainty.
- Reference normative standards for unit notation and measurement practice.
- Provide worked examples relevant to the expected user context (sensor loops, USB devices, power supplies).
Converting between amps and milliamps is deterministic and trivial mathematically, yet attention to measurement precision, rounding, and documentation practice ensures engineering reliability and repeatability.